CYANElite 290 user training

On this page, you will learn how to use your CYANElite 290.

Let's start with the warranty registration.

1. Activate the warranty!

This registration enables you to activate the instrument's warranty and benefit from the peace of mind, manufacturer support (performed through the distributor), notices of important updates, and many more advantages.

It takes about 2 minutes to register your instrument. Don't miss out!

2. The first use

In this video, we present the accessories of the CYANElite 290 and the analyzer’s first use. We recommend this video to all lab technicians in anticipation of the delivery and installation of the CYANElite 290 automated biochemistry analyzer. You will learn how convenient the setup is, and you will be better prepared to start testing.

3. Loading of the reagents

In this video, we show how to load reagents on the CYANElite 290 analyzer and how to match them in the software.

Does your CYANElite 290 have the latest software version?

We recommend using the latest CYANElite 290 Software version: 1.4.3.113

This version fixes some minor bugs, thereby making the CYANElite 290, even more, user-friendly. This new software is fully compatible with all existing CYANElite 290 instruments. We advise you to upgrade all CYANElite 290 analyzers already installed in the field to ensure that all users can benefit from the improved functions.

Get the best user training?

4. Calibrate your CYANElite 290

When, how and why calibrate the CYANElite 290? Performing calibrations and using quality controls regularly is an essential laboratory practice. It gives scientific validity to the reported results. Calibration is necessary because it influences the calculation factors. Verifying and correcting these factors contributes to accurate measurements, which is fundamental for producing conclusive clinical test results

5. Quality Controls

In this video, we demonstrate how to program and schedule quality controls on the CYANElite 290 analyzer. Performing calibrations and using quality controls regularly is an essential laboratory practice. It gives scientific validity to the reported results.

Good to know

 

Calibration is necessary because it influences the calculation factors.

Verifying and correcting these factors contributes to accurate measurements, which is fundamental for producing conclusive clinical test results

 

Perform regular Quality Controls

Quality Controls in the range are an objective confirmation of the clinical validity of your results
It is also a legal requirement and good laboratory practice.

6. Test patient samples

How to program and analyze patient samples on the CYANElite 290 automated biochemistry analyzer? In this video, we show you how to do it.

7. Urgent samples

See how to run urgent samples on the CYANElite 290

8. Replacing the cuvettes

How to replace cuvettes or reagents on the CYANElite 290 biochemistry analyzer? This video shows how to replace reagents and reaction cuvettes during a run.

9. Replacing cuvettes or reagents while the analyzer is running

This video shows how to replace reagents and reaction cuvettes during a run.

10. Refilling the washing solution

Learn how to refill the washing solution

11. Big workloads

In this video we share recommendations for more efficient use of the CYANElite 290 when approaching or exceeding 290 tests per day. These tips relate to: 1. Programming 10 samples in the software 2. Checking how many tests you can still do with the amount of reagents on board 3. Operator notification of a low number of cuvettes and what to do when there are no more cuvettes available (but tests are still scheduled) and what actions can be taken in this case.

Check the other CYANElite 290 videos

We have a dedicated page with 12 other videos relating to using and maintaining the CYANElite 290.

These videos cover useful information from analyzer presentation to biochemistry basics.

Check the other CYANElite 290 videos

12. Can we help you?

Let us guide you step by step to the solution

With our The CYANElite 290 Helper, we give quick and to-the-point advice on how to handle: out of range auto zero values, out of range reagent blanks, calibration issues, quality controls issues

L'assistance au format embarqué :

Related documentation

CYANElite 290

CYANElite 290

Unit | CY015

CYANElite 290 Washing Solution

CYANElite 290 Washing Solution

6 x 50 mL | CY015-WS